Fire Systems
Ordering Info
Napco Commercial Fire Kits
Conventional Fire System Peripherals
GEMC-FK1 | LCD Fire Red Annunciator (Menu-driven operation, functionality for Reset, Acknowledge, Silence (with disable). |
---|---|
GEMC-F8ZCPIM | Conventional 8-zone 2-wire fire input module. Plugs into motherboard, for conventional 2-wire smoke detectors or any conventional fire detection device. |
GEMC-EZM8 | 8-point Expansion Module |
FWC-CNV-PULL | Conventional Single Action Pull Station, with Hex Reset |
FWC-CNV-PULLK | Conventional Single Action Pull Station, with Key Reset |
FWC-CNV-PULL2 | Conventional Dual Action Pull Station, with Hex Reset |
FWC-CNV-PULL2K | Conventional Dual Action Pull Station, with Key Reset |
Wireless Firewolf Peripherals
GEMC-WL-SMK | Gemini Commercial Wireless Smoke, Photoelectric (complete). |
---|---|
GEMC-WL-HEAT | Gemini Commercial Wireless Heat, 135º F |
GEMC-WL-WD2 | Gemini Comml Wireless Input Module converts any UL listed device into a UL wireless device (ex., pull stations or sprinkler supervisories.) |
GEMC-REVC | Gemini Commercial Wireless 255 point RF Receiver (up to 4 per system, max.) |
GEMC-WL-CO | Wireless Carbon Monoxide Detector |
Addressable Firewolf Peripherals
GEMC-FW-SLC | Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices, below.Up to 2 connect to Panel. |
---|---|
FWC-FSLC-SMK | Addressable Analog SLC Smoke, photoelectric, head** |
FWC-FSLC-HEAT | Addressable Analog SLC Heat, 135 - 150ºF, head** |
FWC-FSLC-DUCT | Addressable SLC Duct smoke detector, photoelectric (Requires use of GEMC-24VR Voltage Regulator) Inclds 2 onboard relays that follow state of detector. |
FWC-FSLC-DUCTRA | Remote Indicator Plate with LED indicator & key reset. |
FWC-FSLC-EZM2 | Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indep. contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices. |
FWC-FSLC-EZM1 | Addressable SLC 1-input conventional module, similar to usage above. |
FWC-FSLC-CZM | Addressable SLC Conventional Zone module, for montoring of dry contacts, ie., pull stations and conv. smokes (Requires use of GEMC-24VR Voltage Regulator) Creates a 24V 2-wire fire zone on the SLC loop, selectable Class A or B zone wiring. |
FWC-FSLC-RM2 | Addressable SLC 2-output module (requires 2 SLC addresses) |
FWC-FSLC-ISO | Addressable SLC Short Circuit Module (Optional: For special applications, meets Class A, Style 7 loop reqts.) |
FWC-FSLC-SOM1 | Addressable SLC Fire supervised output module. Application examples: elevator recall, HVAC shutdown, add’l NAC output w/ power supply (Requires use of GEMC-24VR Voltage Regulator) |
FWC-FSLC-PULL | Addressable SLC Fire Pull Station, standard hex-key reset. |
FWC-FSLC-PULLK | Addressable SLC Fire Pull Station, with key reset. |
FWC-FSLC-PULL2 | Dual action, pull station with hex-key reset. |
FWC-FSLC-PULL2K | Dual action pull station, with key reset. |
FWC-FSLC-PROG2 | Tool for address-programming SLC devices |
FWC-FSLC-SMK6B | Smoke/Heat 6 Base, required for FWC-FSLC- SMK and –HEAT devices |
Output Options
GEMC-NAC7S | Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16" can, connects to 120VAC, supports 24V 16Ah standby batts. Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs; 2 low voltage; 1 high-voltage 120V rated relay. |
---|---|
GEMC-12V2APS-CF | 12VDC Power Supply for Fire Bus, remote supervised. Direct 120VAC connection, supports 2ea. 12V, 7Ah to 16Ah standby batts. |
GEMC- FPRINT | Parallel Printer Module |
GEMC-RM3008 | 8 Form C Relay Output Module |
GEMC-RS232 | RS232 Adapter for serial output from Panel |
GEMC-OUT8 | PGM Output Module, 8 open collector PGM outputs |
Communication Options
GEMC-NL-MOD | Internet Reporting Module |
---|---|
SLE-CDMA-FIRE | StarLink Universal Sole Path Fire Cellular Communicator, CDMA Network, works with virtually any 12-24V FACP, virtually anywhere in US. Verizon Network Certified. Meets or exceeds UL864 9th Ed., 1610, 985,1023,1635 & NFPA 72 2013, 2010, 2007 code. |
SLE-GSM-FIRE | StarLink Universal Sole Path Fire Cellular Communicator GSM Network, as above, but communicates on GSM 3/4G Cellular Network. |
- Products
- Keypads
- Napco Detectors
- Gemini Wireless
- Connected Home
- Messenger
- Video
- Virtual Keypads
- Starlink Communications
- Intrusion Communicators
- Connected Home Communicators
- Commercial Fire Communicators
- Fire Alarm Systems
- Napco Commercial
- Access Control
- Gem-Touch
- We're Here to help...
- Contact Us
- Comments